Contents
- Which case would make you consider splinting, and why?
- What should splinting improve?
- Does splinting help with fewer loose screws?
- Does splinting preserve bone?
- Do splinted implants have better implant survival?
- Does ‘short’ automatically mean ‘splint’?
- 2018 ITI Consensus
- Should narrow implants be splinted?
- Why crown height matters more than the ratio
- How could a connector help?
- Loose screw troubleshooting
- Can the patient clean what you connect?
- Which implant in a splint is most at risk?
- Give the middle implant extra attention
- Is there a mechanical reason to splint?
- The decision tree
- When individual crowns remain reasonable
- So, should you splint?
- Frequently asked questions
Which case would make you consider splinting, and why?

Case A: Two well-positioned implants, favourable dimensions, manageable loading, good restorative space.
Case B: Two extra-short posterior implants, tall crowns, substantial lateral loading.
What should splinting improve?

Survival does not mean free of problems.
Bottom line: Splinting can help one of these without helping the others, so let’s analyze them one at a time.
Does splinting help with fewer loose screws?
- Clelland 2016 (trial). 18 patients, split mouth – prospectively comparing splinted vs non-splinted implants. Screw loosening only occurred on the non-splinted side for 5/15 patients. Majority were 6mm length.
- Hsu 2019 (retrospective). Retrospective study, 183 posterior restorations on aftermarket CAD/CAM abutments, about 6 years. Screw loosening: 15 of 86 unsplinted, 0 of 97 splinted.
- Kim 2026 (retrospective). 102 patients, 242 implants. Lower crown height space was associated with biological complications (likely hygiene issue). No clear difference: mechanical problems at 11% of splinted, 5% of single sites.
- Pascoal 2025 (systematic review). Combined 7 studies of adjacent posterior implants. Splinted implants had a third of the risk of repairable problems (loose screws, loose crowns, repairable chips).
Summary: Most studies seem to agree that splinted crowns get fewer loose screws.
Does splinting preserve bone?
Pooled data shows no benefit. On average, splinted implants lost 0.11 mm more bone.

Bottom line: No meaningful benefit either way. The accumulated difference was small and favoured single crowns. Individual studies have shown changes either way by about 0.1 mm.
Do splinted implants have better implant survival?
- Older studies, 2003 to 2016 (de Souza Batista 2019 review). Single crowns failed about 3 times as often. Failure risk ratio, single versus splinted: 3.18 (1.93 to 5.25). Includes older implant ex hex designs and immediate loading.
- Internal-connection implants only (same review). No clear difference with these implants. Failure risk ratio, single versus splinted: 1.95 (0.86 to 4.44), P = .11.
- 2025 review: internal-connection posterior implants (Pascoal 2025). No clear difference in implants lost or mobile. Risk ratio, splinted versus single: 1.02 (0.59 to 1.76).
Summary: With modern implants, splinting has not been shown to help implants survive. Splinting benefits are more for mechanical reasons, rather than survival.
Does ‘short’ automatically mean ‘splint’?
| Study | Implants | What they found |
|---|---|---|
| Li 2022, review | 8.5 mm or shorter | No clear difference in survival, splinted or single |
| Al-Sawaf 2020, trial | 7 mm, lower jaw | Every implant survived 3 years in both groups |
| Tallarico 2020, trial | 6 mm | No failures in either group at 1 year (abstract only) |
| Clelland 2016, trial | Mostly short, many 6 mm | Screw loosening occurred only on the nonsplinted side, mostly involving 6 mm implants; one nonsplinted 6 mm implant failed. |
Opinion: I favour splinting adjacent 6 mm implants to share load and help limit mechanical complications. A survival advantage remains uncertain, but that does not remove the clinical rationale for splinting.
2018 ITI Consensus
In its section on short implants (6 mm or less), the 2018 ITI consensus states:
“the clinical recommendation is made to splint restorations involving adjacent short implants.”

Summary: The ITI advises splinting adjacent implants of 6 mm or less. Being an expert consensus: the studies behind it splinted every case, so there was no comparison with single crowns.
Should narrow implants be splinted?
- Guidance (consensus). ITI 2018: splinting narrow implants (3.5 mm or less) “may be advisable”, depending on the case.
- Laboratory. Two splinted 3.0 implants resisted fatigue better than one implant. Failure at 488N (splinted) vs 118N (single 3.0). (Terrats, 2024)
- Clinical. A study of 102 posterior 3.3 mm implants reported fewer technical complications with splinted crowns over an average of 3.6 years. (Al-Aali, 2019)
Summary: Adjacent narrow implants are an important reason to consider splinting.
Why crown height matters more than the ratio

The taller crown is a longer lever, so lateral forces cause more bending.
- Longer lever: A sideways bite bends a tall crown harder at the screw joint: more loose screws, more broken abutments.
- Harder to clean: Tall crowns sit where bone was lost, so the crown margin is deeper and harder for a brush to reach.
Yi 2023, 888 implants over 15 years: longer crowns meant more loose screws, broken abutments and mucositis. The ratio was not a clear predictor.
Bottom line: Judge crown height, not just the ratio: a tall crown is a longer lever on the screw and harder to clean.
How could a connector help?

Joining two crowns lets a lateral force on one crown spread to both implants.
Summary: A connector can spread load, but stress can also shift to the other implant.
Loose screw troubleshooting
- Check fit
- Check components and the prescribed torque protocol
- Assess crown form and contacts
- Assess parafunction
- Then consider whether load sharing would help
Summary: Find and fix the cause first. In one study, splinting did not stop screw fractures, but after new screws and flatter cusps, none were reported.
Can the patient clean what you connect?

- Yi 2023 (observational). 888 implants, about 13 years: more peri-implantitis around splinted implants.
- Raabe 2026 (observational). Tissue-level implants, 25 years: no clear difference.
Bottom line: Splinting is not proven to cause peri-implantitis, and a well-designed bridge can be cleaned. Only splint if the patient can pass a brush under every connector.


Which implant in a splint is most at risk?

- Ravidà 2019 (observational). 382 implants, about 6 years: middle implant 23.1% when splinted, 5% under single crowns.
- Yi 2020 (observational). Same pattern with bone-level implants, not tissue-level ones.
Summary: In a 3 unit splinted prosthesis, the middle implant has the highest risk of acquiring peri-implantitis. Ensure the design helps to facilitate hygiene to reduce it.
Give the middle implant extra attention

To clean around the middle implant, the brush must pass under both connectors.
Uneven platform levels were linked to more bone loss when implants were splinted.
Bottom line: If you join three, plan cleaning access under both connectors and keep the platforms level.
Is there a mechanical reason to splint?
Consider splinting when
| Situation | Evidence |
|---|---|
| 6 mm or shorter | Fewer screw-loosening problems with splinting in a small split-mouth study; but a five-year 6 mm trial found no clear overall benefit. (Clelland, 2016; Esposito, 2023) |
| Narrow, 3.5 mm or less | Fewer technical complications with splinting in a retrospective study of 3.3 mm implants (Al-Aali, 2019) |
| Tall crowns | More problems with each extra mm of crown; splinting cut stress in a computer model. (Yi, 2023; Güngör Erdoğan, 2026) |
| Molars, male patients | Higher mechanical risk; whether splinting lowers it is untested. (Yi, 2023) |
| Heavy side loads | Splinting helped most under angled loads in lab tests. (Yilmaz, 2011; Wang, 2002) |
| Soft bone | Advised in an expert guide; less bone stress in a computer model. (Ravidà, 2018; Wang, 2002) |
| Grinding, clenching | Advised in an expert guide, but untested; many studies left grinders out. (Ravidà, 2018; Kim, 2026) |
| A cantilever | Splint, in an expert decision tree. (Ravidà, 2018) |
Not reasons on their own
| Situation | Evidence |
|---|---|
| Upper or lower jaw | No reliable evidence either way. (Li, 2022) |
| Grafted sinus | Too few cases to tell. (Afrashtehfar, 2021) |
| External-hex connection | Reviews disagree. (de Souza Batista, 2019; Li, 2022) |
| Ratio above 2 | Single crowns did well up to about 2.1. Check crown height instead. (Meijer, 2018) |
The decision tree
- Is there a mechanical reason? No: Single crowns are a good option. Yes: Use the table above.
- Assess and take into consideration: Occlusion, Passivity, Torque, contacts.
- Does the splint pass every design check?
- A passive fit
- A brush passes under every connector
- Emergence under 30°, not convex (bone-level)
- Implant platforms at the same level
- Three or more joined: plan the middle implant
No: Rethink the design. Yes: Splint, with a maintenance plan.
Summary: Splint for mechanical reasons, and with a design the patient can clean.
When individual crowns remain reasonable
- Appropriate implant dimensions and positions
- Manageable loading
- Good restorative geometry
- Cleanable contours
- A workable maintenance plan
Consider single crowns for:
- Patients with poor dexterity or hygiene
- Three or more adjacent implants
Opinion: Personally I prefer splinting where possible as the proximal contacts are easier to manage. Creating cleansable gingival embrasures while maintaining appropriate connector size is important.
So, should you splint?
Depends, splint when there is a mechanical reason, and ensure the patient can clean the design.
What the evidence says
- Fewer loose screws: the clearest benefit.
- No proven survival benefit with modern implants.
- No meaningful bone benefit.
- Cleaning needs planning, especially around a middle implant.
Case A: Favourable conditions: single crowns are reasonable.
Case B: Extra-short implants, tall crowns, side loads: consider splinting, if it can be cleaned.
Frequently asked questions
Does splinting implants reduce screw loosening?
Most studies seem to agree that splinted crowns get fewer loose screws.
Does splinting improve implant survival?
With modern implants, splinting has not been shown to help implants survive. Splinting benefits are more for mechanical reasons, rather than survival.
Should adjacent short implants be splinted?
The ITI advises splinting adjacent implants of 6 mm or less. I favour splinting adjacent 6 mm implants to share load and help limit mechanical complications.
About the author
Dr Jonathan Ng, BDSc (Hons), MSc Advanced Dental Implantology, Fellow ICOI, is an implant dentist in Brisbane and the Federal President of the Australian Osseointegration Society. He has placed more than 2,000 implants since 2017 and teaches full-arch reconstruction to dentists across Australia and Asia through Source Education.
References
- Afrashtehfar KI, Katsoulis J, Koka S, Igarashi K. Single versus splinted short implants at sinus augmented sites: a systematic review and meta-analysis. J Stomatol Oral Maxillofac Surg. 2021;122(3):303-310. doi:10.1016/j.jormas.2020.08.013
- Al-Aali KA, ArRejaie AS, Alrahlah A, AlFawaz YF, Abduljabbar T, Vohra F. Clinical and radiographic peri-implant health status around narrow diameter implant-supported single and splinted crowns. Clin Implant Dent Relat Res. 2019;21(2):386-390. doi:10.1111/cid.12718
- Al-Sawaf O, Tuna T, Rittich A, Kern T, Wolfart S. Randomized clinical trial evaluating the effect of splinting crowns on short implants in the mandible 3 years after loading. Clin Oral Implants Res. 2020;31(11):1061-1071. doi:10.1111/clr.13652
- Clelland N, Chaudhry J, Rashid RG, McGlumphy E. Split-mouth comparison of splinted and nonsplinted prostheses on short implants: 3-year results. Int J Oral Maxillofac Implants. 2016;31(5):1135-1141. doi:10.11607/jomi.4565
- de Souza Batista VE, Verri FR, Lemos CAA, Cruz RS, Oliveira HFF, Gomes JML, et al. Should the restoration of adjacent implants be splinted or nonsplinted? A systematic review and meta-analysis. J Prosthet Dent. 2019;121(1):41-51. doi:10.1016/j.prosdent.2018.03.004
- Esposito M, Gatti F, Meloni M, Muzzi L, Baldini N, Buti J, Minciarelli A. To splint or not to splint short dental implants under the same partial fixed prosthesis: five-year results from a multicentre randomized controlled trial. Clin Trials Dent. 2023;5(3). doi:10.36130/ctd.03.2023.02
- Güngör Erdoğan H, Keleş M, Yılmaz B. Comparison of stress distribution around splinted and nonsplinted implants with different crown height space in posterior mandible: a finite element analysis study. J Prosthodont. 2026;35(7):1124-1133. doi:10.1111/jopr.13935
- Hsu KW, Wei PC, Chen YL, Liou EJW. Retrospective and clinical evaluation of aftermarket CAD/CAM titanium abutments supporting posterior splinted prostheses and single crowns. Int J Oral Maxillofac Implants. 2019;34(5):1161-1168. doi:10.11607/jomi.7365
- Jung RE, Al-Nawas B, Araujo M, Avila-Ortiz G, Barter S, Brodala N, et al. Group 1 ITI Consensus Report: the influence of implant length and design and medications on clinical and patient-reported outcomes. Clin Oral Implants Res. 2018;29(Suppl 16):69-77. doi:10.1111/clr.13342
- Kim DY, Pang EK, Choi SH, Lee JB. Comparison of complications between splinted and nonsplinted implants placed in the posterior region. Int J Oral Maxillofac Implants. 2026;41(1):45-52. doi:10.11607/jomi.11251
- Li QL, Yao MF, Cao RY, Zhao K, Wang XD. Survival rates of splinted and nonsplinted prostheses supported by short dental implants (≤8.5 mm): a systematic review and meta-analysis. J Prosthodont. 2022;31(1):9-21. doi:10.1111/jopr.13402
- Lin GH, Lee E, Barootchi S, Rosen PS, Curtis D, Kan J, et al. The influence of prosthetic designs on peri-implant bone loss: an AO/AAP systematic review and meta-analysis. J Periodontol. 2025;96(6):634-651. doi:10.1002/JPER.24-0144
- Lin GH, Tran C, Brzyska K, Kan JY, Wang HL, Curtis DA, et al. The significance of vertical platform discrepancies and splinting on marginal bone levels for adjacent dental implants. Clin Implant Dent Relat Res. 2023;25(2):321-329. doi:10.1111/cid.13176
- Meijer HJA, Boven C, Delli K, Raghoebar GM. Is there an effect of crown-to-implant ratio on implant treatment outcomes? A systematic review. Clin Oral Implants Res. 2018;29(Suppl 18):243-252. doi:10.1111/clr.13338
- Papaspyridakos P, De Souza A, Vazouras K, Gholami H, Pagni S, Weber HP. Survival rates of short dental implants (≤6 mm) compared with implants longer than 6 mm in posterior jaw areas: a meta-analysis. Clin Oral Implants Res. 2018;29(Suppl 16):8-20. doi:10.1111/clr.13289
- Pascoal ALB, Paiva KRG, Marinho LCN, Bezerra AS, Calderon PS. Impact of splinting implant-supported crowns on the performance of adjacent posterior implants: a systematic review and meta-analysis. J Prosthet Dent. 2025;133(2):402-410. doi:10.1016/j.prosdent.2024.05.020
- Prete BRJ, Silva MAJ, Wong BC, Deporter DA. A pattern of peri-implantitis affecting middle implants in 3-implant splinted prostheses. Clin Adv Periodontics. 2024;14(4):284-289. doi:10.1002/cap.10274
- Raabe C, Fonseca M, Roccuzzo A, Schimmel M, Salvi GE, Chappuis V, et al. Crestal bone loss and peri-implant conditions at tissue-level implants: influence of prosthesis type after 25 years. Clin Implant Dent Relat Res. 2026;28(3):e70158. doi:10.1111/cid.70158
- Ravidà A, Saleh MHA, Muriel MC, Maska B, Wang HL. Biological and technical complications of splinted or nonsplinted dental implants: a decision tree for selection. Implant Dent. 2018;27(1):89-94. doi:10.1097/ID.0000000000000721
- Ravidà A, Tattan M, Askar H, Barootchi S, Tavelli L, Wang HL. Comparison of three different types of implant-supported fixed dental prostheses: a long-term retrospective study of clinical outcomes and cost-effectiveness. Clin Oral Implants Res. 2019;30(4):295-305. doi:10.1111/clr.13415
- Tallarico M, Gatti F, Meloni SM, Muzzi L, Baldini N, Buti J, et al. To splint or not to splint short dental implants under the same partial fixed prosthesis? One-year post-loading data from a multicentre randomised controlled trial. Clin Trials Dent. 2020;2(1):47-58. doi:10.36130/CTD.02.2020.04 (abstract only)
- Terrats RG, Liñares MB, Punset M, Molmeneu M, Nart Molina J, Ruíz Magaz V, et al. Influence of narrow titanium dental implant diameter on fatigue behavior: a comparison between unitary and splinted implants. J Clin Med. 2024;13(6):1632. doi:10.3390/jcm13061632
- Toniollo MB, Macedo AP, Pupim D, Zaparolli D, de Mattos MGC. Finite element analysis of bone stress in the posterior mandible using regular and short implants, in the same context, with splinted and nonsplinted prostheses. Int J Oral Maxillofac Implants. 2017;32:e199-e206. doi:10.11607/jomi.5611
- Vigolo P, Mutinelli S, Zaccaria M, Stellini E. Clinical evaluation of marginal bone level change around multiple adjacent implants restored with splinted and nonsplinted restorations: a 10-year randomized controlled trial. Int J Oral Maxillofac Implants. 2015;30(2):411-418. doi:10.11607/jomi.3837
- Wang TM, Leu LJ, Wang JS, Lin LD. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis. Int J Oral Maxillofac Implants. 2002;17(2):231-237.
- Yi Y, Heo SJ, Koak JY, Kim SK, Koo KT. Splinting or nonsplinting adjacent implants? A retrospective study up to 15 years: Part I, biologic and mechanical complication analysis. Int J Oral Maxillofac Implants. 2023;38(3):435-442. doi:10.11607/jomi.10053
- Yi Y, Koo KT, Schwarz F, Ben Amara H, Heo SJ. Association of prosthetic features and peri-implantitis: a cross-sectional study. J Clin Periodontol. 2020;47(3):392-403. doi:10.1111/jcpe.13251
- Yilmaz B, Seidt JD, McGlumphy EA, Clelland NL. Comparison of strains for splinted and nonsplinted screw-retained prostheses on short implants. Int J Oral Maxillofac Implants. 2011;26(6):1176-1182.