Dental Implant

How to place a pterygoid implant safely: a step-by-step guide

A pterygoid implant placed close to vertical through the tuberosity and pterygoid process on a 3D anatomy model

Anatomy of the pterygoid: a view from the buccal

3D anatomy render from the buccal showing the medial and lateral pterygoid plates, the tuberosity and the maxillary artery, with the optimum angulation of a pterygoid implant arrowed

It is important not to angle laterally, especially with a long implant as you may hit the maxillary artery resulting in severe bleeding.

A view from the palatal

3D anatomy render from the palatal showing the tuberosity, pterygoid process, pyramidal process and the greater and lesser palatine arteries, with a red ring where an implant started too mesially would meet the greater palatine artery

Starting too mesial may result in the implant impinging on the greater palatine artery (GPA). You can use the GPA as a landmark so that you start alongside it so you do not hit the GPA.

Key landmark: the hamulus of the medial pterygoid plate

Close 3D view of the hamulus, the sharp process at the lower end of the medial pterygoid plate

This sharp process can be felt in the mouth intra-orally. Place your finger posterior and medial to the tuberosity and palpate to feel a protrusion. Once you identify this you now know where the medial plate is. Don’t angle your implant beyond that point medially.

Two CBCT surface reconstructions of the hamulus of the medial pterygoid plate, a view from the anterior and a view from the posterior

It’s important to be aware that the hamulus is not necessarily in line with where the bulk of the medial plate is, but it’s a reference marker for you in the mouth. You would then determine from the CBCT where the medial plate is, in relation to the hamulus landmark you have palpated intra-orally.

Anatomy: engage all 3 bones

3D anatomy render labelling the three bones a pterygoid implant engages: the pterygoid process, the pyramid process of the palatine bone and the tuberosity

The goal is to engage the pterygoid implant through all 3 bones: “tuberosity, pyramid process of the palatine bone, and pterygoid process”.

How to visualize it on CBCT

Two axial CBCT slices with a traced panoramic curve: on the left the curve stops short and does not cross the pterygoid plates, on the right it extends back through the lateral and medial plates

A mistake people make when trying to locate the pterygoid structures on CBCT is not tracing the panoramic curve far enough distally. Ensure that when tracing the panoramic curve, it extends beyond the pterygoid plates!

Key landmark: the hamular notch

Intra-oral photograph of an elevator walked distal to the tuberosity into the hamular notch
Feel the drop with your elevator.

It is really important to identify the distal termination of the tuberosity and feel your elevator drop when it goes distal to the tuberosity, this is the hamular notch. Now you have a landmark to measure against (how many mm your start point is mesial to it). Your start point is anywhere between 5-15 mm away depending on your angulation. Explanation coming up below.

Medial angulation: popping out between the two plates

3D render of a pterygoid implant on the anatomical model emerging in the space between the medial and lateral pterygoid plates, with an angle gauge overlaid

The “easiest” trajectory to aim for when placing pterygoids is to pop out between the two pterygoid plates. Tactilely you will feel a slight ‘drop’ when you emerge in the space between the cortical plates. Furthermore we always aim medially as going laterally can run the risk of impinging on the maxillary artery. So if there’s one rule to remember it’s go medially when placing pterygoids!

CBCT planning screens for a pterygoid implant planned to come out between the medial and lateral plates, with the 3D segmentation at bottom right showing the apex emerging between the plates

Here is an example of a CBCT plan with the pterygoid planned to come out between the two plates. Notice on the bottom right you can visualize the apex coming out between the two plates on the CBCT segmentation.

Medial angulation: engaging into the medial plate

3D render of a pterygoid implant angled to engage into the medial pterygoid plate rather than emerge between the plates

When trying to achieve even more stability sometimes we aim to engage into the medial plate of the pterygoid. This is a harder target to hit. There is also anatomical variation so it is important to palpate the hamulus to identify the position of the medial plate. When engaging into the medial plate you shouldn’t feel a ‘drop’ in the drill as you are not emerging out from cortical bone. If you do you may be in the nasopharynx OR the descending palatine artery (that connects to the GPA) which means you drilled too far or you went too medial.

CBCT planning screens for a pterygoid implant planned to engage into the medial plate, with the descending palatine canal labelled and no apex visible between the plates in the 3D segmentation

Here is an example of a CBCT plan with the pterygoid planned to engage into the medial plate. Note you can’t see the apex emerging at all between the two plates on the bottom right segmentation.

The pterygomaxillary pillar

3D render from the buccal of the pterygomaxillary fissure where the maxillary artery exits, with the vertical extent of the pterygomaxillary pillar marked
A visual of the pterygomaxillary fissure where the maxillary artery exits.

The pterygomaxillary pillar is essentially the mating points between the 3 bones, tuberosity, pyramidal process of the palatine bone and pterygoid processes. There is a vertical extent to this.

3D render from the palatal of the pterygomaxillary pillar, with the tuberosity, pyramidal process and pterygoid process labelled
A view from the palatal.

The more we can engage into this pillar the more stability we will get.

Implant angulation

Palatal 3D view of a pterygoid implant placed close to vertical, with a long run of thread against the pterygomaxillary pillar

The more ‘vertical’ the pterygoid implant is placed the more contact area there is between the threads and the dense mating of the 3 bones. This is the angulation that would achieve the most torque however the sacrifice is access, given the implant is placed more distally.

The same palatal 3D view with the pterygoid implant at about 45 degrees, with less thread against the pterygomaxillary pillar

Compare the image above to a more standard ‘45 degree’ angulation. You can see that with this angulation the pterygoid implant doesn’t come into contact with as much of the pterygomaxillary pillar.

Two CBCT planning views of the same site: at 37 degrees the implant path has 6.56 mm of cortical engagement, at 16 degrees it has 11.22 mm

Note the difference in the length of cortical bone engagement between a 16 degrees angulation vs 37 degrees angulation on this real CBCT analysis while planning for a pterygoid implant in the same site. Simply changing angulation can result in up to 5 mm more cortical engagement here!

Putting it together in a full-arch case

Radiographs and CBCT sections of finished pterygoid implants at the 18 and 28 sites
Pterygoid implants at the 18 site and the 28 site.

We start with the pterygoids first, despite being freehand we can use anatomical landmarks to gauge how to place our pterygoid implants freehand.

Two panoramic radiographs: a maxilla with very pneumatised sinuses before treatment, and the same maxilla restored with tilted implants riding the anterior sinus walls and pterygoid implants posteriorly

When faced with a maxilla with very pneumatized sinuses, the key is to place the tilted implants as posterior as possible ‘riding’ the anterior sinus wall. In combination with pterygoid implants it’s possible to achieve a sufficient AP spread.

Frequently asked questions

Which way should you angle a pterygoid implant?

We always aim medially as going laterally can run the risk of impinging on the maxillary artery. So if there’s one rule to remember it’s go medially when placing pterygoids!

How do you find the hamulus of the medial pterygoid plate?

Place your finger posterior and medial to the tuberosity and palpate to feel a protrusion. Once you identify this you now know where the medial plate is. Don’t angle your implant beyond that point medially.

Where do you start a pterygoid implant?

Identify the hamular notch. Now you have a landmark to measure against (how many mm your start point is mesial to it). Your start point is anywhere between 5-15 mm away depending on your angulation.

About the author

Dr Jonathan Ng, BDSc (Hons), MSc Advanced Dental Implantology, Fellow ICOI, is an implant dentist in Brisbane and the Federal President of the Australian Osseointegration Society. He has placed more than 2,000 implants since 2017 and teaches full-arch reconstruction to dentists across Australia and Asia through Source Education.